How do I tell what is wrong with my air conditioner?

Start with the symptom. An AC that runs but blows warm air usually has an outdoor unit that has stopped running. One that is completely dead is often a tripped float switch or breaker. Water indoors is almost always a clogged condensate drain. Match the symptom below to narrow the cause.

None of what follows replaces a real diagnosis, and none of it requires you to open anything electrical. The point is to tell you what is probably happening, whether it is something you can check yourself in two minutes, and how urgent it is.

Match your symptom to a likely cause

Common AC symptoms in North Texas and where they usually lead
SymptomMost common causeCheck yourself firstUrgency
Runs constantly, house drifts warmerLow refrigerant charge, or a dirty condenser coilLook at the outdoor coil. If it is packed with cottonwood, grass clippings or hail damage, that is a real lead.Soon — running low on charge stresses the compressor
Indoor fan blows, but the air is warmOutdoor unit has stopped — often a failed run capacitorGo outside and listen. If the indoor blower runs but the outdoor fan is still, that narrows it sharply.Soon
Completely dead, no response at allTripped condensate float switch, or a breakerCheck the breaker panel, and look for a full drain pan at the indoor unit.Same day if the house is heating up
Water on the floor near the indoor unitClogged condensate drain lineLook for standing water in the drain pan. Shut the system off to stop the overflow.Urgent — this is an active water damage risk
Ice on the refrigerant line or coilAirflow restriction, most often a filter left in far too longCheck the filter. Turn the system to fan-only to thaw it before anything else.Turn it off now — running a frozen system can slug the compressor
Loud rattle or clatter outdoorsDebris in the condenser, or a failing fan motor bearingLook through the top grille for storm debris. Common after North Texas thunderstorms.Soon
Blank or unresponsive thermostatLoss of power upstream — frequently the float switch againTry fresh batteries, then check the indoor unit for a full drain pan.Soon
Upstairs hot, downstairs coldDuct design and attic heat gain, not usually a broken partNothing to check — this is a system design conversation.Not urgent, but it will not fix itself
Guidance for narrowing a symptom, not a diagnosis. Anything requiring a panel to be opened is a service call — do not open electrical enclosures.

Two symptoms that mean turn it off now

Most AC problems can wait until morning. Two should not. If you see ice on the coil or refrigerant line, shut the system off — running a frozen system risks returning liquid refrigerant to the compressor, which turns a cheap repair into an expensive one. And if there is water coming from the indoor unit, shut it off to stop the overflow before it reaches drywall or ceiling below.

A burning smell, or a breaker that trips again immediately after being reset, also means stop. A breaker that keeps tripping is doing its job — it is reporting a fault, not causing one, and resetting it repeatedly is how a bad situation becomes a dangerous one.